MSA Altair 2XP Gas Detector, H2S-pulse (10, 15), Charcoal with Xcell Pulse Technology - 10153984
Item #:
10153984
Brand:
MSA
Share this product:
10153984 Altair 2XP Gas Detector, H2S-pulse (10, 15), Charcoal with Xcell Pulse Technology by MSA
Introducing the ALTAIR 2X Gas Detector from MSA; the first one or two gas detector that incorporates industry-leading XCell Sensor Technology to deliver unparalleled performance while drastically minimizing total cost of ownership, increasing durability and delivering enhanced worker safety, compliance and traceability.
The Altair 2X is also the first portable gas detector to introduce revolutionary XCell Pulse Technology. Based on proven science and advanced patented sensor capabilities, the Altair 2XP detector delivers the world's first stand-alone bump test. This allows a daily bump test to be performed without the need for calibration accessories or specific calibration gas.
ALTAIR 2XP Gas Detector – with xCell Pulse Technology
The Altair 2XP gas detector provides a bump test that is so easy to follow, anyone can do it, from anywhere! The science behind this first-of-its-kind technology will change the face of portable gas detection as we know it. By combining pulse sensor interrogation with a simple flow check, we've created the first successful stand-alone bump test. PULSE sensor interrogation begins, exhale into the unit. And the result? You're BUMPEd!
ALTAIR 2xT – Two-Tox Gas Detector
The ALTAIR 2XT Detector eliminates the need for a second detector by utilizing proven XCell Two-Tox Sensors. XCell Two-Tox Sensors detect two gases on distinct sensor channels with digital output that minimizes cross channel interference.
ALTAIR 2X – Single Gas Detector
MSA revolutionized gas detection with XCell Sensor Technology. By miniaturizing the sensors' controlling electronics and placing them inside the sensor itself using MSA's proprietary application-specific integrated circuit (ASIC) design, MSA XCell Sensors offer superior stability, accuracy, and sensor life.
Features & Benefits
Low cost of ownership
- Fastest sensor response times, lowest calibration gas flow rate on the market
- 4-year expected instrument & sensor life
- 3-year warranty on instrument & most sensors (2 years on Cl2, NH3)
- Stand-alone bump tests reduce maintenance, increase productivity (ALTAIR 2XP only)
- 1 device can monitor 2 gases (ALTAIR 2XT only)
Increased safety awareness & real-time compliance
- Stand-alone bump test anytime, anywhere without specific calibration gas (ALTAIR 2XP only)
- Bump pass: green LED flash every 15s, large on-screen checkmark
- Bump fail or expiration: red LED flash every 15s, no checkmark
- End-of-sensor-life warning and alarm
Full-time traceability
- Records 75 alarm events
- 150+ hours of periodic data (ALTAIR 2X and 2XP)
- 100+ hours of periodic data (ALTAIR 2XT)
- Compatible with MSA GALAXY® GX2 Automated Test System and MSA Link Pro software
Rugged durability
- Tough over-molded rubber armor
- Survives multiple 25-ft drops onto concrete
- Agency-certified dust- and water-tight IP67 construction
- Intrinsically-safe design
Size | 3.5" l x 2.125" W x 1.25" d (no clip) |
Weight | 4 oz (113 g) w/ clip |
Housing | Rugged rubberized armor |
Ingress Protection | IP67 |
Drop Test | 25 feet |
Handling | One-handed, one-button operation |
Bump Test Indicators | Pass: Green LED flash & checkmark Fail or expiration: Red LEd flash only |
Audible Alarm | 95 db @ 1 foot |
Visual Alarm | Ultra-bright LEDs |
Vibrating Alarm | Standard |
Display | Large-character monochrome LCD |
Backlight | 10s backlight w/ adjustable timeout |
Battery | Replaceable lithium battery |
Extended Temp. Range | -20°C to +50°C |
Extreme Range | -40°C to +60°C |
Data Log | 2X/2XP: > 150 hrs 2XT: > 100 hrs |
Event Log | 75 events |
Standard Warranty | Chassis & electronics: 3 years Cl2 & NH3 sensors: 2 years All other sensors: 3 years Does not cover consumable parts. |
Datasheets & User Manuals
-
Bulletin: ALTAIR 2X Gas Detectors
Data Sheet: ALTAIR 2X Gas Detectors FAQ
Data Sheet: ALTAIR 2X Gas Detectors Introduction
Technical Brief: MSA XCell Pulse Technology; Flow Check - Exhalation Test
Technical Brief: MSA XCell Pulse Technology; Pulse Check
Technical Brief: MSA XCell Pulse Technology Detectors; Stand-Alone Bump Testing
Technical Brief: MSA XCell Two - Tox Sensors
Poster: ALTAIR 2XP Gas Detector
Operating Manual: ALTAIR 2X Single or Two Gas Detector